Electric Motor Water Pump
-
Hollow Shaft Motor
-
3 Phase Induction Motor
-
Single Phase Induction Motor
-
IE2 Motor
-
IE3 Motor
-
Pool Pump Motor
-
Hydraulic Pump Electric Motor
-
Centrifugal Water Pump
-
Peripheral Water Pump
-
Self Priming Pump
-
Automatic Water Pump
-
Multistage Centrifugal Pump
-
Deep Well Pump
-
AC Electric Generator
-
Open Diesel Generator
-
Easy Spare Parts
-
Vadim ZabiiakaZhongzhi does really good on the design and manufacturing of the products. Experienced engineers service us very nice.
-
Mr.Reuben kimwoloGood quality, great manufacturers, we are happy with your products.
-
Mr.Yılmaz TürkoğluHave been working together for more than 3 years very professional. all products work fine in our types of equipment. Thank you.
IE2 Standard Three Phase Induction Motor , AC Electric Motor 4 Pole 380V 50HZ
Place of Origin | FUAN CHINA |
---|---|
Brand Name | ZOZHI |
Certification | CE,ISO |
Model Number | IE2 MS112M-4 |
Minimum Order Quantity | 10pcs |
Price | negotiated |
Packaging Details | Packed in cartons,veneer case or wooden case. |
Delivery Time | 25 working days after received your payment |
Payment Terms | T/T |
Supply Ability | 10000pcs/month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xName | IE2 Motor | Output | 4kw/5.5Hp |
---|---|---|---|
Voltage | 230/400V/60HZ | Winding Material | 100% Copper Wire |
Standard | IEC 2 | Housing | Aluminum |
Pole | 4 | Phase | 3 Phase |
Highlight | high efficiency induction motor,high efficiency ac motor |
IE2 Standard Three Phase Induction Motor / A.C. Electric Motor 380V 50HZ
IE2 Motor Description
IE2 series motors with the mounting dimension by standard IEC60034 have good features like optimum structure, attractive appearance, low noise, high efficiency, high protection class, and high insulation class. Therefore, YE2 series motors can be widely used in various kinds of general use machinery like fans, pumps, machine tools, compressors, transportation, and so on, and can also be used in hazardous areas with oil and chemical, steel plants, mining industry.
- Site conditions
IE2 series motors are suitable for almost all applications and operate satisfactorily at temperatures from -20℃to +40℃and altitudes up to 1000 meters above sea level
- Temperature and Insulation
The Maters' insulation system is designed by Class F(155℃), operated with Class B(80K), which increases the motor's useful life and reliability.
- Cooling and ventilation
The standard cooling method is Enclosed Fan Cooled (TEFC) by IC411 of IEC60034-6. Standard motors are equipped with radial-flow plastic fans.
- Protection class
The standard degrees of protection are IP55. The IP55 enclosure means complete hose proof and dustproof protection. A higher degree of protection is available.
- Motor protection
Motors can be installed with PTC, PT100, such as winding and bearing temperature measurement, and other kinds of protection on request.
- Voltage and frequency
Standard voltage and frequency are 380V 50HZ and can be wound for any single voltage in the range 200-660V at a frequency of 50. The motors will operate satisfactorily with variations of ±5% from the rated voltage.
- Vibration
YE2 motors are designed for vibration class A; vibration class B is available on request.
- Terminal box location
The terminal box at the top or right of the frame is the standard YE2 motor.
- Quality assurance
Stringent quality system observed from the first design to finished products by the ISO9001 documented quality system.
- Motor working system
This series of motors working system for S1 continuous duty.
Operating conditions
|

IE2 Motor Technical Data
Model | Power | (V) | (A) | (r/min) | Eff. (%) | P.F. | Ist/In | Tmax/Tn | |||
Kw | HP | 50% | 75% | 100% | |||||||
IE2 MS801-2 | 0.75 | 1 | 230/400 | 3.0/1.73 | 2800 | 76.5 | 77.3 | 77.4 | 0.813 | 2.2 | 2.3 |
IE2 MS802-2 | 1.1 | 1.5 | 4.2/2.43 | 2800 | 79 | 80 | 79.6 | 0.825 | 2.2 | 2.3 | |
IE2 MS90S-2 | 1.5 | 2 | 5.53/3.19 | 2820 | 80.2 | 81.5 | 81.3 | 0.837 | 2.2 | 2.3 | |
IE2 MS90L-2 | 2.2 | 3 | 7.93/4.58 | 2820 | 82.2 | 83.5 | 83.2 | 0.837 | 2.2 | 2.3 | |
IE2 MS100L-2 | 3 | 4 | 10.5/6.06 | 2830 | 84 | 85.1 | 84.6 | 0.848 | 2.2 | 2.3 | |
IE2 MS112M-2 | 4 | 5.5 | 400/690 | 7.97/4.6 | 2850 | 85.4 | 86.8 | 85.8 | 0.848 | 2.2 | 2.3 |
IE2 MS132S1-2 | 5.5 | 7.5 | 10.65/6.15 | 2870 | 86.7 | 87.3 | 87 | 0.86 | 2 | 2.3 | |
IE2 MS132S2-2 | 7.5 | 10 | 14.35/8.28 | 2870 | 87.6 | 88.3 | 88.1 | 0.86 | 2 | 2.3 | |
IE2 MS160M1-2 | 11 | 15 | 20.74/11.97 | 2900 | 89 | 89.8 | 89.4 | 0.86 | 2 | 2.3 | |
IE2 MS160M2-2 | 15 | 20 | 27.99/16.16 | 2900 | 90 | 90.5 | 90.3 | 0.86 | 2 | 2.3 | |
IE2 MS160L-2 | 18.5 | 25 | 33.83/19.53 | 2900 | 90.3 | 91 | 90.9 | 0.872 | 2 | 2.2 | |
IE2 MS802-4 | 0.75 | 1 | 230/400 | 3.28/1.9 | 1380 | 77.3 | 79.8 | 79.6 | 0.72 | 2.3 | 2.3 |
IE2 MS90S-4 | 1.1 | 1.5 | 4.57/2.64 | 1400 | 79.9 | 81.7 | 81.4 | 0.743 | 2.3 | 2.3 | |
IE2 MS90L-4 | 1.5 | 2 | 6.02/3.48 | 1400 | 82.1 | 83.5 | 82.8 | 0.755 | 2.3 | 2.3 | |
IE2 MS100L1-4 | 2.2 | 3 | 8.42/4.86 | 1420 | 82.6 | 84.5 | 84.3 | 0.778 | 2.2 | 2.3 | |
IE2 MS100L2-4 | 3 | 4 | 11.32/6.54 | 1420 | 84.2 | 85.7 | 85.5 | 0.778 | 2.2 | 2.3 | |
IE2 MS112M-4 | 4 | 5.5 | 400/690 | 8.47/4.89 | 1430 | 85.8 | 87 | 86.6 | 0.79 | 2.2 | 2.3 |
IE2 MS132S-4 | 5.5 | 7.5 | 11.18/6.45 | 1450 | 87.4 | 88.3 | 87.7 | 0.813 | 2.2 | 2.3 | |
IE2 MS132M-4 | 7.5 | 10 | 14.85/8.58 | 1450 | 88.2 | 89 | 88.7 | 0.825 | 2.2 | 2.3 | |
IE2 MS160M-4 | 11 | 15 | 21.84/12.61 | 1460 | 89.1 | 90 | 89.8 | 0.813 | 2.2 | 2.3 | |
IE2 MS160L-4 | 15 | 20 | 29.08/16.79 | 1460 | 90.2 | 91.1 | 90.6 | 0.825 | 2.2 | 2.3 | |
IE2 MS90S-6 | 0.75 | 1 | 230/400 | 3.82/2.2 | 910 | 73.4 | 76.3 | 75.9 | 0.65 | 2 | 2.2 |
IE2 MS90L-6 | 1.1 | 1.5 | 5.25/3.03 | 910 | 77 | 78.8 | 78.1 | 0.673 | 2 | 2.2 | |
IE2 MS100L-6 | 1.5 | 2 | 6.77/3.91 | 940 | 79.6 | 80.8 | 79.8 | 0.697 | 2 | 2.2 | |
IE2 MS112M-6 | 2.2 | 3 | 9.69/5.59 | 940 | 80.4 | 81.6 | 81.8 | 0.697 | 2 | 2.2 | |
IE2 MS132S-6 | 3 | 4 | 12.56/7.25 | 960 | 81 | 83.4 | 83.3 | 0.72 | 2 | 2.2 | |
IE2 MS132M1-6 | 4 | 5.5 | 400/690 | 9.36/5.4 | 960 | 82.7 | 84.5 | 84.6 | 0.732 | 2 | 2.2 |
IE2 MS132M2-6 | 5.5 | 7.5 | 12.47/7.2 | 960 | 84.8 | 86.2 | 86 | 0.743 | 2 | 2.2 | |
IE2 MS160M-6 | 7.5 | 10 | 16.78/9.69 | 970 | 86.4 | 87.5 | 87.2 | 0.743 | 2 | 2 | |
IE2 MS160L-6 | 11 | 15 | 24.19/13.97 | 970 | 88.2 | 89.2 | 88.7 | 0.743 | 2 | 2 |
Performance comparison chart:
ELECTRIC MOTOR EFFICIENCY VALUES-4POLES 1500 RPM | ||||
Power(kw) | eff2 (nominal) | eff1 (nominal) | IE2 (nominal) | IE3 (nominal) |
0.75 | - | - | 79.6 | 82.5 |
1.1 | 76.2 | 83.8 | 81.4 | 84.1 |
1.5 | 78.5 | 85.0 | 82.8 | 85.3 |
2.2 | 81 | 86.4 | 84.3 | 86.7 |
3.0 | 82.6 | 87.4 | 85.5 | 87.7 |
4.0 | 84.2 | 88.3 | 86.6 | 88.6 |
5.5 | 85.7 | 89.2 | 87.7 | 89.6 |
7.5 | 87 | 90.1 | 88.7 | 90.4 |
11 | 88.4 | 91.0 | 89.8 | 91.4 |
15 | 89.4 | 91.8 | 90.6 | 92.1 |
18.5 | 90 | 92.2 | 91.2 | 92.6 |
22 | 90.5 | 82.6 | 91.6 | 93.0 |
30 | 91.4 | 93.2 | 92.3 | 93.8 |
37 | 92 | 93.6 | 92.7 | 93.9 |
45 | 92.5 | 93.9 | 93.1 | 94.2 |
55 | 93 | 94.2 | 93.5 | 94.6 |
75 | 93.6 | 94.7 | 94.0 | 95.0 |
90 | 93.9 | 95.0 | 94.2 | 95.2 |
110 | 94.5 | 95.4 | ||
132 | 94.7 | 95.6 | ||
160 | 94.9 | 95.8 | ||
200...375 | 95.1 | 96.0 |
High-efficiency motor features
(1) High efficiency, IE2 is 3% higher than IE1 on average, and IE3 is about 5% higher than IE1 on average.
(2) We Need to use more high-quality materials. IE2 motor cost is 25% -30% higher than IE1, and IE3 motor cost is about 40% -60% higher than IE1.
(3) Due to the lower operating temperature and longer motor life, maintenance costs can be reduced.
(4) The starting current is larger under typical design conditions.
(5) The rotor inertia is large.
(6) The rotation speed is higher under the rated load, and the slip rate is lower